Single sided#

  1. Assemble the wall mounting if delivered disassembled.

  2. Drill appropriate number of anchoring holes in the wall for wood‑type screws of 6 mm diameter. Use the mounting console as a template.

  3. Mount the console on the wall and put it into a fully tilted out position.

  4. Shift the clock body into the flipped out console arms and fix it by tightening the Allen screws.

  5. Dismantle the back connector cover on the clock body; the cover incorporates gap with sealing for passage of cables in the inside of the clock.

  6. Arrange all cables to appropriate length and connect them to appropriate terminals on the PCB; see the description of the connectors and observe the correct polarity where necessary.

    Attention

    If the clock is synchronized by LGC variant, please navigate to Clock Operation Non-Network Clock Operation to get detailed info about connection of various synchronization sources and receivers.

    For LGC variant, check and configure the position of DIP switch according to used synchronization signal (applies only for DCF, MOBALine, polarized impulse line or IRIG‑B).

  7. Fix the cables with the holder in correct positions in order to maintain regular spacing between the cables in the area of passing through sealing; use appropriate force to not to damage the cables insulation.

  8. Mount back the connector cover.

  9. Tilt the clock into vertical position and fix the position of the console.