DT.180 technical parameters#
Display |
180.1C.1T |
180.1C.2T |
180.1C.3T |
180.2C.1T |
180.2C.2T |
---|---|---|---|---|---|
digit height |
180 mm |
||||
number of rows |
2 |
3 |
4 |
3 |
4 |
number of time displays |
1 |
1 |
1 |
2 |
2 |
number of temperature displays |
1 |
2 |
3 |
1 |
2 |
viewing distance |
70 m |
Synchronization |
|
---|---|
NTP |
NTP protocol, mains powered |
WiFi |
WiFi 2.4 GHz, NTP protocol, mains powered |
WiFi5 |
WiFi 2.4/5 GHz, NTP protocol, mains powered |
GPS |
GPS signal, mains powered |
LGC |
MOBALine, MOBATIME serial code, impulse line, DCF, DCF-IMP (Timecode, Active DCF), IRIG-B |
Power |
||
---|---|---|
mains powered |
100–240 VAC, 50–60 Hz |
|
VDC option |
18–55 V (see VDC voltage) |
|
VDISP option |
supply voltage depends on display color (see VDISP voltage table) |
Power consumption |
180.1C.1T |
180.1C.2T |
180.1C.3T |
180.2C.1T |
180.2C.2T |
---|---|---|---|---|---|
single sided |
30–36 VA |
45–69 VA |
60–92 VA |
45–69 VA |
60–92 VA |
Quartz base and running reserve |
||
---|---|---|
running reserve |
96 hours by means of supercapacitor or 2 years with lithium battery |
|
accuracy |
±0.3 s/day |
Accuracy of temperature management (for TP3/30m) |
||
---|---|---|
range -55 to -10 °C |
±2.0 °C |
|
range -25 to +85 °C |
±0.5 °C |
|
range -50 to +125 °C |
±2.0 °C |
Operating environment |
||
---|---|---|
temperature |
-25 to +65 °C |
|
humidity |
0 to 95 % (without condensation) |
|
protection degree |
IP 65 |
Range of measured temperature |
||
---|---|---|
range |
-25 to +65 °C |
Weight |
180.1C.1T |
180.1C.2T |
180.1C.3T |
180.2C.1T |
180.2C.2T |
---|---|---|---|---|---|
single sided |
24 |
35 |
44 |
35 |
44 |
Dimensions |
180.1C.1T |
180.1C.2T |
180.1C.3T |
180.2C.1T |
180.2C.2T |
---|---|---|---|---|---|
single sided W x H x D [mm] |
940 |
940 |
940 |
940 |
940 |