Ceiling Suspension Mounting#
The double sided clock consists of two parts, one serving as the control module (this one encompasses the jacks to connect powering voltage, synchronization source, the temperature sensor and the keyboard to the clock) – “MASTER clock”, and the other one serving as the display module (with the terminal for the connection of the interconnecting cable) – “SLAVE clock”. Both clock parts are interconnected via a 10‑core flat cable. The clock suspension part is delivered separately.
Step 5
1
See chapter Cable Connection.
For mains‑powered clocks, connect the supply conductors to the terminal block on control board according to the label.
Shape or shorten the conductors so that their routing does not obstruct proper positioning and securing of the clock.
For PoE / PoE+ powered clocks, connect a PoE‑enabled Ethernet cable to the RJ‑45 connector on the control board.
Use a PoE switch port or PoE injector that provides the required PoE power.
Connect the wires of the respective component (e.g., temperature sensor, keyboard, or RS‑485 interface) to the terminal block on control board according to the label.
Connect the Ethernet cable to the RJ-45 connector, if available.
Caution
Be careful not to swap the terminals. Check the markings of the terminals on the control board.
Caution
For the LGC variant, set the DIP switch according to the used synchronization signal (its position can be found in the Cable Connection chapter, marked with the letter B).
For lines synchronization, keep the DIP switch in its default position.
For all other synchronization signals (DCF, MOBALine, polarized impulse line, IRIG‑B), set the DIP switch to the DCF position.
See the chapter Clock Operation > Non-network Clock Operation for detailed information about connecting the various synchronization sources and receivers.