Single sided#

  1. Prepare two holes in a wall by hinges pitch on the backside of the clock.

  2. Insert dowels to prepared holes and screw appropriate screws into them.

  3. Remove bottom screws on the clock. Remove bottom cover and front glass.

    ../../_images/eco-m-dsc_glass_removal.svg
  4. Loosen four screws holding display chassis with electrinics. Move the chassis up so screws fit into grooves.

    Hint

    Do not fully unscrew screws.

    ../../_images/eco-m-dsc_display_removal1.svg../../_images/eco-m-dsc_display_removal2.svg
    • ECO-M-DSC.100:

      Disconnect DC power cable from clock control PCB (except PoE / PoE+).

    • ECO-M-DSC.180 / 190: Disconnect DC power cable and flat data cable from most left digit.

  5. Remove small cover which includes gap with sealing for passage of cables into the clock.

    ../../_images/eco-m-dsc_sealing_gap.svg
  6. Put cable(s) through the opening and hang the clock on the prepared screws in the wall.

  7. Tight the securing screws which prevent unauthorized demounting of the clock.

  8. Cut all cables to appropriate length and fix them with the holder in correct position in order to maintain regular spacing between the cables in the area of passing through sealing; use appropriate force to not to damage the cables insulation.

  9. Mount back the small cover and tight its screws with appropriate force.

  10. Connect the power cable to appropriate power supply terminals (except PoE / PoE+).

  11. Connect the synchronization / temperature / GPS cable to corresponding terminals on the control PCB and / or crimp the RJ45 jack to the Ethernet cable respectively.

    Attention

    If the clock is synchronized by LGC variant, please navigate to Clock Operation Non-Network Clock Operation to get detailed info about connection of various synchronization sources and receivers.

    For LGC variant, check and configure the position of DIP switch according to used synchronization signal (applies only for DCF, MOBALine, polarized impulse line or IRIG‑B).

  12. Power connection:

    • ECO-M-DSC.100:

      Connect the synchronization / temperature / GPS cable to corresponding terminals on the control PCB and / or crimp the RJ45 jack to the Ethernet cable respectively.

    • ECO-M-DSC.180 / 190:

      Connect DC power cable and flat data cable back to most left digit.

  13. Connect DC power cable and flat data cable back to most left digit.

  14. Mount back the front glass and bottom cover.