Current Limits#
Setting of current limits for outputs.
In Service menu press the button to select Current limits and proceed to enter its setting by pressing button.
The display shows following:
L1: 250 DC: 50
Accu: 50 A: 0.1W
L1: 250:Current limit for slave line (current, which is reached, master clock reports overload state)
DC: 50:Current limit for 24 V output
Accu: 50:Current limit for Accu (14 V) output
A: 0.1W:Available power in Watts, which can be distributed into ouputs (cannot be set)
The current limits are in mA.
Summary available power (A:) is calculated by formula:
P[W] = 8.3 – Accu[A] × 14 + (Line[A] + DC[A]) × 25
Button function
- :
Enter item setting
- :
Return to
Service menu
Button function in ‘item edit’ mode
- :
Move between items
- :
Switch flasing item (holding down the button will cycle through the options)
- :
Save edited values and return to page view
- :
Exit without save and return to page view
After setting desired current limits, press the button to confirm your choice. The display shows Saved and returns to page view.
Default Values#
- Slave line:
L1: 250[mA]- Output 24V:
DC: 70[mA]- Output 14V:
Accu: 200[mA]
Limits for Outputs#
- Slave line:
L1: 250[mA]- Output 24V:
DC: 200[mA]- Output 14V:
Accu: 200[mA]