Basic Data#

Mouting

Rack height

1U

Slave clock line

Number of slave clock lines

1

Types

Polarized minute / half-minute / second impulses

MOBATIME serial code

MOBALine

Electrical parameters

12 / 24 V, max. 150 mA

Switching relay contact

Number of switching relay contacts

2

Weekly program

With up to 399 switching contacts

Astronomical calendar

With entry of geographical coordinates for surise / sunset calculation

Manual switching

Selection of different control modes

Electrical parameters

Max. 250 VAC, max. 6 A, 1500 VA

Other I/O

Input of DCF signal

GPS input for external antenna

Output of DCF signal (synthetic passive)

USB for recording / playback of switching programs

Mono audio, output 3.5 mm jack

2 outputs (1 on rear side / 1 on front panel)

Output for battery charging

14 VDC, max. 200 mA

Output VDC

24 VDC, max. 200 mA

Back-up at Power Loss

Passive for RTC

About 5 years by lithium battery

Active for full functionality

Internal circuit for charging the external battery

Power Supply

AC (mains)

115 or 230 VAC ±5 %, 50–60 Hz

DC

24 VDC ±5 %; 13 VDC ±10 %

Accuracy (at approx. 20 °C)

Without synchronization

±0.1 s/day (after 24 hours of synchronization at constant temperature)

With synchronization

± 10 ms

Operating environment

Operating temperature

-30 to +70 °C

Relative humidity

Max. 95 % (without condensing)

Protection degree

IP 40

Weight

Standard

1.5 kg

Dimensions

Standard

483 × 44 × 127 mm