Basic Data#
Mouting |
|
|---|---|
Rack height |
1U |
Slave clock line |
|
|---|---|
Number of slave clock lines |
1 |
Types |
Polarized minute / half-minute / second impulses MOBATIME serial code MOBALine |
Electrical parameters |
12 / 24 V, max. 250 mA |
Switching relay contact |
|
|---|---|
Number of switching relay contacts |
2 |
Weekly program |
With up to 399 switching contacts |
Astronomical calendar |
With entry of geographical coordinates for surise / sunset calculation |
Manual switching |
Selection of different control modes |
Electrical parameters |
Max. 250 VAC, max. 6 A, 1500 VA |
Other I/O |
|
|---|---|
Input of DCF signal |
✓ |
GPS input for external antenna |
✓ |
Output of DCF signal (synthetic passive) |
✓ |
USB for recording / playback of switching programs |
✓ |
Mono audio, output 3.5 mm jack |
2 outputs (1 on rear side / 1 on front panel) |
Output for battery charging |
14 VDC, max. 200 mA |
Output VDC |
24 VDC, max. 200 mA |
Back-up at Power Loss |
|
|---|---|
Passive for RTC |
About 5 years by lithium battery |
Active for full functionality |
Internal circuit for charging the external battery |
Power Supply |
|
|---|---|
AC (mains) |
115 or 230 VAC ±5 %, 50–60 Hz |
DC |
24 VDC ±5 %; 13 VDC ±10 % |
Accuracy (at approx. 20 °C) |
|
|---|---|
Without synchronization |
±0.1 s/day (after 24 hours of synchronization at constant temperature) |
With synchronization |
± 10 ms |
Operating environment |
|
|---|---|
Operating temperature |
-30 to +70 °C |
Relative humidity |
Max. 95 % (without condensing) |
Protection degree |
IP 40 |
Weight |
|
|---|---|
Standard |
1.5 kg |
Dimensions |
|
|---|---|
Standard |
483 × 44 × 127 mm |