Firmware Update#

Note

This setting is available only when the USB flash drive is connected to the USB connector.

1

Click here or navigate to the url https://docs.mobatime.cloud/HN-61c.R/firmware to download the latest firmware file – version v1.3.0.

Place the file hn60.enf into root directory of USB flash drive. Insert the USB flash drive into USB connector. In Service menu press the > button to select Firmware update and proceed to run the firmware update process by pressing v button.

The display shows following:

Firmware update
100 %  Running

On the display is displayed progress of the firmware update and update state. Update progress is displayed in percentage value. Update state is in form of text.

Available text fields:

Error:

On the USB flash drive is not detected correct file (either the file is not present or the file is for other type of master clock)

Running:

Update process in progress

Reset:

Waiting for the master clock update

Warning

During the update process, do not touch any buttons.

Warning

During the update process, do not disconnect the USB flash drive.

After the update process ends, the master clock restarts and return to screen MASTER. Then it is possible to check on the screen VERSION if the firmware version is correct. If not, repeat the whole procedure.