Classic Striking on the Bells or Dulcimers#

This function is used to set the parameters and type of ringing on bells or dulcimers using electric bell strikers. Switching of electric hammers is realized by means of additional module HN…SSR2. By default, striking is disabled.

When activated, the display shows following:

Strike off22-05h
1/2 I02 P18 Ph10
off22-05h:

Striking off period

1/2:

Striking type

I02:

Impulse length

P18:

Gap length

Ph10:

Gap length between 1/4 and hour striking at 1/4 striking type

Button function in ‘item edit’ mode

< >:

Move between items

+ -:

Switch flasing item (holding down the button will cycle through the options)

v:

Save edited values and return to page view

x:

Exit without save and return to page view

Striking Types#

You can set following striking types:

1/4:

Output 1 is always activated at the 15th, 30th, 45th and 00th minute

Output 2 is activated at the full hour with the number of hour strikes

1/2:

Output 1 is always activated on 30th minute (1 strike) and on the full hour with the number of hour strikes

1/1:

Output 1 is always activated at the full hour with the number of hour strikes

1/0:

Output 1 is always activated at the full hour (1 strike)

Number of strikes / Output#

Striking type

15th minute

30th minute

45th minute

60th minute

full hour

1/4 [1]

1 / OUT 1

2 / OUT 1

3 / OUT 1

4 / OUT 1

1–12 / OUT 2

1/2

1 / OUT 1

1–12 / OUT 1

1/1

1–12 / OUT 2

1/0

1 / OUT 1