Power Supply – Parameters and Options#
Power source [1] |
230 VAC ± 10 % |
24 VDC ± 5 % |
13 VDC ± 10 % |
|---|---|---|---|
Power supply terminal |
L N PE |
VDC |
|
Voltage at the ACCU terminal |
14 VDC |
– |
|
Max. possible current consumption from ACCU terminal [2] |
200 mA |
– |
|
Voltage at the VDC terminal |
24 VDC |
– |
24 VDC |
Max. possible current consumption from VDC terminal [2] |
200 mA |
– |
200 mA |
Impulse line voltage |
24 V |
||
Active operation reserve (Pb accumulator) |
✓ |
– |
|
Fitted jumper ACCU connect [3] |
– |
✓ |
|
Voltage type |
AC voltage, sine 50–60 Hz |
DC voltage, stabilized and smoothed |
|