Generation 3 Digital Clock#

Setting IP Address of Sensor to Clocks#

  1. Enter the digital clock main menu, navigate to r6.__ (version) item.

  2. Hold down the PB1 and PB2 buttons or the DISP button on the remote control and proceed to enter the service menu.

  3. Navigate to item C5, proceed to enter the item and set the value to 3.

  4. Proceed to enter the item C5: 3 to set 4 octects of the temperature sensor IP address.

  5. If you have two temperature sensors, proceed to enter the item C5: 4 and repeat the previous step.

  6. Leave the service menu.

  7. The digital should display correct temperature within 3 minutes.

Setting Temperature Correction#

Temperature sensors may have inherent inaccuracies or drift over time. If this is the case, you can set the temperature correction on display by following this procedure:

  1. Enter the digital clock main menu, navigate to the P12 submenu and proceed to enter.

  2. The c1: 0 is displayed, the set correction is flashing. Change the flashing item to desired value in range -9 to +9 (°C or °F).

  3. If you have second temperature sensor, navigate to item c2: 0 and repeat the previous step.

  4. Save the values and return to main menu by pressing the PB1L or OK on the remote control.