Installation#
Warning
The following places should be avoided:
Within the reach of high voltage operated equipment.
Places exposed to direct impact of solar radiation.
Installation Procedure#
Mount the carillon components on the DIN rail 9M.
Terminate all supply cables at the terminal block at the top of the cabinet, connect the outputs at the bottom of the terminal block to the inputs of the modules HN…SSR2 according to the diagram in chapter Carillon Connection.
Connect the outputs (module HN…SSR2) for the striking hammers (1–2) to the striking hammers (minimum CYKY 2x1,5).
The wall-mounted cabinet has holes for the supply cables at the top or bottom of the cabinet.
Connect the GPS antenna.
Switch on the 230 V mains voltage. The current time will appear on the control clock display.