Single Sided#

Note

Mounting is for DA.45.6 / DA.57.6.

  1. The frame is fixed using two suspension (above) and two sliding (bottom) springs. Lift‑off the anchoring plate using a screwdriver inserted in between the sheet and the frame at the sliding spring point on the clock bottom side.

  2. Disconnect the interconnecting cables by decoupling the terminals on the control PCB.

  3. Drill three anchoring holes into the wall, of a diameter adequate to accommodate wood‑type screws of 4–5 mm diameter. As a template for marking the position of the holes, the anchoring plate can be used.

  4. Interlace the incoming conductors through the opening in the anchoring plate and fix the sheet to the wall.

  5. Connect the incoming conductors in accordance with the descriptive sheet on the terminal board, placed on the anchoring plate. Give the conductors an appropriate shape or cut them off to a length that will not obstruct the placement of the clock onto the anchoring plate.

  6. Mount the connectors to the cable of the temperature sensor, to the keyboard, Ethernet cable or to the RS-485 interface connectors if these are used.

    Attention

    If the clock is synchronized by LGC variant, please navigate to Clock Operation Non-Network Clock Operation to get detailed info about connection of various synchronization sources and receivers.

    For LGC variant, check and configure the position of DIP switch according to used synchronization signal (applies only for DCF, MOBALine, polarized impulse line or IRIG‑B).

  7. Push the temperature sensor connector, the keyboard connector, Ethernet connector or the RS-485 jacks into the corresponding terminal on the control PCB.