Unicast Mode#

The clock is synchronized to UTC (Universal Time Coordinate) from NTP server (up to four IPv4 / IPv6 addresses for NTP server configurable) and must have assigned its own IPv4 / IPv6 address. The clock requests in defined intervals the actual time from NTP server (interval can be adjusted in NEt menu item n9). If the server is not available, the clock tries to contact other defined servers in cyclic ways until valid response from NTP server is received.

This operation mode supports monitoring and configuration of movement via network connection by means of Web Interface (enabled in NEt menu item n15 setting the value to 1), SNMP (enabled in NEt menu item n14 setting the value to 1) or MOBA-NMS Software Tool.

For supervision and configuration with MOBA-NMS, either clock’s IPv4 / IPv6 address can be used or multicast group address (NEt menu item n7) must have last octet cleared to zero (presuming that the multicast is not disabled – NEt menu item n13 is not set to value 0).

See also

It is necessary to set appropriate timezone for correct displaying of local time and date. More details can be found in: