Line Type Settings#

The display shows following:

L1      type:min
cykH imp15 gap15
min:

Slave line type

cykH:

Cycle

imp15:

Line type length

gap15:

Gap length

Button function in ‘item edit’ mode

< >:

Move between items

+ -:

Switch flasing item (holding down the button will cycle through the options)

v:

Save edited values and return to page view

x:

Exit without save and return to page view

Options#

Slave Line Type#

Select slave line type according to slave clock type:

min:

For clocks controlled by minute impulses

1/2m:

For clocks controlled by half-minute impulses

sec:

For clocks controlled by second impulses

code:

For clocks controlled by MOBATIME serial code

Cycle#

Select pulse lines cycle according to mode in which slave clock operates:

H:

Half-day, 12 hours (analogue clock)

D:

Daily, 24 hours (digital clock)

Impulse Parameters#

Impulse Line Length#

Enter the pulse duration in tenths of seconds:

imp(01-99):

Pulse duration in tenth of seconds

Gap Length#

Enter the length of gap between pulses in fast-forward mode in tenths of seconds:

gap(01-99):

Gap length in tenth of seconds