View and Edit Sequece Records of Carillon#
The display shows following:
1:- 2:-
000.0:Activation time of the record since the selected sequence was triggered in
[s][s][s].[ms]format
1:-,2:-:Striking hammer outputs
Button function
- :
Move between records
- :
Add new record
- :
Delete selected record
- :
Edit selected record
- :
Return to sequence selection
Button function in ‘item edit’ mode
- :
Move between items
- :
Switch flasing item (holding down the button will cycle through the options)
- :
Save edited record
- :
Exit without save and return to list of records
Options#
Enter following data step-by-step:
Offset#
Offset [s][s][s].[ms]:Set the offset step-by-step.
Caution
Set a gap of atleast 1 s between each record in the sequence.
1
If the previous record has an offset of 2.0 s and the length of the longest pulse is 0.8 s, the next record should have an offset of at least 2.9
Striking Hammer Outputs#
For every striking hammer output (1:- and 2:-) set desired option:
General Notes#
Caution
Do not store the first record in the sequence at time 0.0 s, because this time defines the gap between repeating the sequence.
Note
Individual records are sorted in ascending order according to the offset parameter.
Note
Individual records must be inserted with respect to the specified pulse length for the hammers.
Note
Maximum length of 1 sequence can be up to 999.9 s.
Note
The maximum total number of all records in all sequences is 1000.