Double sided#

  1. Double-sided clock consists of two parts - MASTER display (this part encompasses a terminal to connect supply voltage and synchronization source) and SLAVE display (this part encompasses a terminal for connection of interconnecting cable). Both clock parts are interconnected via 10-core flat cable.

  2. Connect the 10-core interconnecting cable into corresponding plug on clock control PCB of the SLAVE display.

Caution

The cable must never be connected or disconnected while power on MASTER display is on.

  1. Drill four anchoring holes into a ceiling / a wall of a diameter adequate to accommodate supplied wood-type screws with dowels.

  2. Interlace incoming cables through suspension pipe. Fasten the ceiling suspension / the wall bracket to ceiling / wall using 4 wood-type screws of 5 mm diameter.

  3. Interlace incoming cables through pipe insert on anchoring plate. Slip-on the plate onto suspension in a way that screws fit into upper groove on pipe insert. Fix the connection by tightening the screw using Allen key.

  4. Hang the SLAVE display to one side of the anchoring plate.

  5. Shorten all incoming cables appropriately.

  6. Mount a wide 2-pin connector to incoming powering cable.

  7. Mount a 2-pin connector to synchronization signal cable or crimp RJ45 modular connector to incoming Ethernet cable.

  8. Connect all interconnecting cables into corresponding connectors in back side recess.

    Attention

    If the clock is synchronized by LGC variant, please navigate to Clock Operation Non-Network Clock Operation to get detailed info about connection of various synchronization sources and receivers.

    For LGC variant, check and configure the position of DIP switch according to used synchronization signal (applies only for DCF, MOBALine, polarized impulse line or IRIG‑B).

  9. Hang the MASTER display to other side of the anchoring plate.

    • If the clock has to be tilted down slightly, cut the supporting element on bottom of back side accordingly.

    • Loosen screws on suspension using Allen key and lift the clock into suspension in a way that screws fit into lower groove on pipe insert. Secure the attachement by tightening the screw using Allen key.