Line Type Settings#
The display shows following:
cykH imp15 gap15
min:Slave line type
cykH:Cycle
imp15:Line type length
gap15:Gap length
Button function in ‘item edit’ mode
- :
Move between items
- :
Switch flasing item (holding down the button will cycle through the options)
- :
Save edited values and return to page view
- :
Exit without save and return to page view
Options#
Slave Line Type#
Select slave line type according to slave clock type:
min:For clocks controlled by minute impulses
1/2m:For clocks controlled by half-minute impulses
sec:For clocks controlled by second impulses
code:For clocks controlled by MOBATIME serial code
MBL:For clocks controlled by MOBALine
Cycle#
Select pulse lines cycle according to mode in which slave clock operates:
H:Half-day, 12 hours (analogue clock)
D:Daily, 24 hours (digital clock)
Impulse Parameters#
Impulse Line Length#
Enter the pulse duration in tenths of seconds:
imp(01-99):Pulse duration in tenth of seconds
Gap Length#
Enter the length of gap between pulses in fast-forward mode in tenths of seconds:
gap(01-99):Gap length in tenth of seconds
Recommended Default Values#
1
Recommended default values for minute and half-minute lines:
imp15:Pulse lenght 1.5 s
gap15:Gap lenght 1.5 s
1
Recommended default values for second line:
imp03:Pulse lenght 0.3 s
gap02:Gap lenght 0.2 s
Note
For second line, imp+gap must not be greater than 10. If imp+gap equals 10, then fast-forward mode is not possible.