Carillon#
This item is used to set the carillon parameters.
In Main menu press the button to select Carillon and proceed to enter its setting by pressing button.
The display shows following:
1:2 2:2 3:2 4:2
T1:00:Minimum repetition time of the activated sequence on input 1 or 2
1S01:Sequence number activated on input I1
2S02:Sequence number activated on input I2
1:2:Output O1; length of output pulses per hammer output in multiples of 100 ms (1–9)
2:2:Output O2; length of output pulses per hammer output in multiples of 100 ms (1–9)
3:2:Output O3; length of output pulses per hammer output in multiples of 100 ms (1–9)
4:2:Output O4; length of output pulses per hammer output in multiples of 100 ms (1–9)
Button function
- :
Move between items
- :
Switch flasing item (holding down the button will cycle through the options)
- :
Save edited values and return to page view
- :
Return to
Main menu
1
To set pulse lengths 0.7, 0.5, 0.6 and 0.3 s, set following:
1:72:53:64:3